It appears that your cart is currently empty

| Code | Description | Check, repair/replace as necessary |
| A5 | Tank NTC defect | check tank NTC and leads |
| A7 | DHW NTC defect | check hot water NTC and connecting lead |
| A8 | EMS coms error | check electrical connections. |
| b1 | Code plug not detected | Insert code plug correctly. |
|
b2,b3,b4, b5,b6 |
Data error | software/pcb error |
| b7 | Burner control error | software/pcb error |
| C6 | Fan defect | check fan, lead and connector. |
| D3 | External Temp limiter | check external stat. |
| D5 | Condensate overflow | check condensate pump and leads. |
| D6 | Internal heatbank overheated | check tank overheat thermostat |
| EA | Burner control lockout | check gas supply and igniter electrode. |
| E2 | Primary NTC defect | check CH NTC and lead. |
| E9 | OH stat tripped | check system pressure and pump. |
| F0 | Internal error | check electrical connector contacts. |
| F1 | Rom check error | software/pcb error. |
| F7 | Flame detected after appliance shut off | check electrode assembly, dry pcb. |
| FA | Flame detected after gas shut off | check gas valve and leads |
| Fd | Reset button pressed | press reset button again. |