| Code | Description | Check, repair/replace as necessary |
| A8 | EMS coms error | check electrical connections |
| b1 | Code plug not detected | Insert code plug correctly |
|
b2,b3,b4, b5,b6 |
Data error | software/PCB error |
| b7 | Burner control error | software/PCB error |
| C6 | Fan defect | check fan, lead and connector |
| D5 | Condensate overflow | check condensate pump and leads. |
| EA | Burner control lockout | check gas supply and igniter electrode |
| E2 | Primary NTC defect | check NTC and lead. |
| E9 | OH stat tripped | Check system pressure and pump |
| F0 | Internal error | check electrical connector contacts. |
| F1 | ROM check error | software/PCB error. |
| F7 | Flame detected after appliance shut off | check electrode assembly, dry PCB |
| FA | Flame detected after gas shut off | check gas valve and leads. |
| Fd | Reset button pressed | press reset button again. |